11 - MESSAGES
ABBREVIATIONS &
NAV TERMS
183
190-00356-00 Rev E
COM transmitter power has been reduced — (GNS
430W/GNC 420W only) Excessive unit temperature and/or
an insufficient voltage level has been detected. The COM
transceiver transmit power has been automatically reduced
to compensate for the condition. For excessive tempera-
tures, check for adequate ventilation or check cooling air
flow. If the message persists, contact your Garmin dealer for
assistance.
Configuration error - Config service req’d — The con-
figuration information provided by the installer has been
lost or corrupted. Contact your Garmin dealer for service.
Data transfer cancelled (crossfill is busy) — An
attempt to transfer flight plan data during a unit-to-unit
crossfill was cancelled. The host unit is busy. Wait until
any previous crossfill operation is complete, before re-
attempting the transfer.
Data transfer cancelled (data invalid) — An attempt
to transfer a single user waypoint during a unit-to-unit
crossfill was cancelled. No waypoint was specified on the
Crossfill Page. Select a user waypoint and re-attempt the
transfer.
Data transfer cancelled (version mismatch) — An
attempt to transfer data during a unit-to-unit crossfill was
cancelled. The database versions of the two 400W-series
unit are not identical. If necessary, update the database(s)
so they match. Contact Jeppesen or your Garmin dealer for
assistance.
Data transfer error, please re-transmit — An error was
detected during unit-to-unit crossfill of user data (user
waypoints and/or flight plans). The data transfer should be
re-attempted.
Data transfer is complete — The unit-to-unit crossfill of
all user waypoint data has finished.
Database changed, validate user modified procedures
You have modified one or more approaches, departures
or arrivals from their original published form. When the
NavData
®
card is replaced (database update), you must
manually verify your changes in the new database. This
message occurs each time a flight plan containing a modi-
fied procedure (generated from a prior database version) is
activated. To eliminate the message, re-create the flight plan
from the new database, then make the desired modific-
ations.
Display backlight failure — The 400W-series unit has
detected a failure in the display backlighting. The unit
should be taken to your Garmin dealer for service.
Do not use for navigation — The 400W-series unit is in
DemoModeandmustnotbeusedforactualnavigation.
FPL has been truncated — The flight plan (FPL) was
truncated because not enough room existed to insert an
approach, departure or arrival. This may occur upon
power up when a database change increases the number of
waypoints within an instrument procedure.
FPL is full — remove unnecessary waypoints — An
attempt has been made to add more than 31 waypoints to
a flight plan (FPL). The 400W-series unit does not allow
more than 31 waypoints per flight plan.
FPL waypoint is locked — At least one flight plan (FPL)
waypoint is locked because the waypoint has been removed
fromthecurrentNavData
®
card (database change), the data
card is missing, or the data card has failed.
FPL waypoint moved — The position data for one or
more flight plan (FPL) waypoints moved at least 0.33 arc
minutesinthecurrentNavData
®
card (database change).
G/S has failed — (GNS 430W only) A failure in the
glideslope receiver has been detected. The glideslope
receiver is not available and the unit should be returned to
your Garmin dealer for service.