Kohler CH18-745 Automobile Parts User Manual


 
11.19
Section 11
Reassembly
11
Figure 11-67. Breather Cover Fastener Torque
Sequence.
Reconnect Rectifier-Regulator
1. Install the rectifier-regulator in the blower housing,
if removed previously, then connect the rectifier-
regulator ground lead with the washer and silver
screw through the eyelet as shown in Figure
11-68. If a grounding bracket is used, secure with
the lower mounting screw and washer, against the
outer side of the rectifier-regulator. See Figure
11-70.
Figure 11-70. Grounding Bracket and Attached
Connector.
SMART-SPARK
Module
1. On engines with SMART-SPARK
, reinstall the
SAM module to the blower housing or cylinder
baffle. Do not over-tighten the retaining screws.
See Figure 11-71.
Figure 11-68. Connecting Ground Lead.
2. Install the B+ terminal/lead into the center position
of the rectifier-regulator plug and connect the plug
to the rectifier-regulator. See Figures 11-69 and
11-70.
1
2
3
4
Figure 11-69. Installing B+ Lead into Plug.
Grounding
Bracket