9.7
Section 9
Disassembly
9
3. Remove the carburetor, throttle linkage and
governor lever as an assembly. See Figure 9-24.
Figure 9-26. Removing Electric Starter Motor.
3. Remove the starter assembly and any spacers (if
used).
Remove Outer Baffles and Blower Housing
1. Disconnect the plug from the rectifier-regulator on
the blower housing. See Figure 9-27.
Remove Electric Starter Motor
1. Disconnect the leads from the starter.
2. Remove the two hex. flange screws. See Figure
9-26.
Figure 9-24. Removing Carburetor Assembly with
Governor Lever Attached.
4. Remove the carburetor gasket.
5. If necessary, the carburetor, throttle linkage and
governor lever can be separated. Reattach the
bushings to the linkage following separation to
avoid losing them.
Remove Oil Sentry
™
(If So Equipped)
1. Disconnect the lead from the Oil Sentry
™
switch.
2. Remove the Oil Sentry
™
switch from the breather
cover. See Figure 9-25.
Figure 9-25. Removing Oil Sentry
™
Switch from
Breather Cover.
Figure 9-27. Disconnecting Plug from Rectifier-
Regulator.
2. Use the tip of the dipstick or a similar small flat
tool to bend the locking tang, then remove the B+
(center lead) from the terminal plug as shown in
Figure 9-28. This will allow the blower housing to
be removed without disturbing the wiring harness.