Novatel MR10/15 GPS Receiver User Manual


 
96 SMART-MR10/15 User Manual Rev 5
B.6 FRESET Clear Selected Data from NVM and Reset
This command is extended to include SMART-MR10/15 features. An additional target field, userdata
(value = 10), resets only the SMART-MR10 (or SMART-MR15) user data NVM, thereby resetting all
parameters indicated in this document as “Stored in NVM” to factory defaults. Issuing the FRESET
command with the “target” field set to standard, resets the userdata NVM as well as OEMV
parameters as indicated in the OEMV Family Firmware Reference Manual.
Table 19: FRESET Target
If you issue the FRESET command without any parameters, it is the same as issuing
a FRESET STANDARD command.
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1 FRESET
header
- - This field contains the
command name or the
message header
depending on whether the
command is abbreviated
ASCII, ASCII or binary,
respectively.
-H0
2 target See Table 19 Data to be reset by the
receiver
Enum 4 H
Binary ASCII Description
0 STANDARD Resets commands, ephemeris, and almanac (default). Also resets all
L-band related data except for subscription information.
1 COMMAND Resets the stored commands (saved configuration)
2 GPSALMANAC Resets the stored GPS almanac
3 GPSEPHEM Resets the stored GPS ephemeris
4 GLOEPHEM Resets the stored GLONASS ephemeris
5 MODEL Resets the currently selected model
10 USERDATA Reset SMART-MR10-only commands
11 CLKCALIBRATION Resets the parameters entered using the CLOCKCALIBRATE command
20 SBASALMANAC Resets the stored SBAS almanac
21 LAST_POSITION Resets the position using the last stored position
31 GLOALMANAC Resets the stored GLONASS almanac