Novatel MR10/15 GPS Receiver User Manual


 
SMART-MR10/15 User Manual Rev 5 95
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1 COM header - - This field contains the command
name or the message header
depending on whether the
command is abbreviated ASCII,
ASCII or binary, respectively.
- H 0
2 port See Table 16,
COM Serial Port
Identifiers on Page
94
Port to configure.
(default = THISPORT)
Enum 4 H
3 bps/baud 300, 600, 900,
1200, 2400, 4800,
9600, 19200,
38400, 57600,
115200, or 230400
Communication baud rate (bps).
Bauds of 460800 and 921600
are also available on COM1 of
OEMV-2-based products.
ULong 4 H+4
4 parity See Table 17,
Parity on Page 94
Parity Enum 4 H+8
5 databits 7 or 8 Number of data bits
(default = 8)
ULong 4 H+12
6 stopbits 1 or 2 Number of stop bits
(default = 1)
ULong 4 H+16
7 handshake See Table 18,
Handshaking on
Page 94
Handshaking Enum 4 H+20
8 echo OFF 0 No echo
(default)
Enum 4 H+24
ON 1 Transmit any input characters as
they are received
9 break OFF 0 Disable break detection Enum 4 H+28
ON 1 Enable break detection (default)