11.25
Section 11
Reassembly
11
Install Electric Starter Motor
1. Install the starter motor using the two hex flange
screws. Position the lift bracket as shown to also
secure the dipstick tube. See Figure 11-79. Some
inertia-drive starters have a pinion cover and
spacers on the starter bolts.
2. Torque the two hex flange screws to 15.3 N·m
(135 in. lb.).
3. On models with a solenoid shift starter, connect
the leads to the solenoid.
CV26, CV745 EFI Engines
Governor Shaft
Configuration
High Idle WOT
Intended
Maximum RPM
Spring Color
Hole No.
Standard
(Parent Material)
3888
3780
3672
3564
3456
3348
3240
3132
3024
3600
3500
3400
3300
3200
3100
3000
2900
2800
Orange
Black
Red
Green
Red
Green
Blue
Clear
Clear
3
3
3
2
2
1
1
1
1
Standard Throttle Control
With WAWB (Wide Area Walk
Behind) Throttle Control
Spring Color
Hole No.
Red
Purple
Blue
Orange
Green
Red
Purple
Blue
Clear
3
3
3
2
2
1
1
1
1
8 mm Governor Lever and Hole Position/RPM Charts cont.
Figure 11-79. Installing Starter and Lift Bracket.
Lift Bracket/Dipstick
Tube Support
Starter
CV750 Engines
Governor Shaft
Configuration
High Idle WOT
Intended
Maximum RPM
Spring Color
Hole No.
Standard
(Parent Material)
3888
3780
3672
3564
3456
3348
3600
3500
3400
3300
3200
3100
Clear
Orange
Blue
Red
Clear
Clear
3
1
1
1
1
1
With Governed Idle Systems
Figure 11-80. Installing Dipstick Tube.
4. Install the dipstick tube and align the mounting
hole with the threaded hole in the lift bracket.
Secure with the M5 hex flange screw. Torque the