8.31
8
Section 8
Electrical System and Components
Figure 8-45. Removing Solenoid Screws.
3. If the solenoid was mounted with Phillips head
screws, separate the solenoid and plunger spring
from the drive end cap. If the solenoid was
mounted with external Torx head screws, the
plunger is part of the solenoid, unhook the
plunger pin from the drive lever. Remove the
gasket from the recess in the housing. See Figures
8-46 and 8-47.
NOTE: Test procedure for checking starter solenoid
on pages 8.39 and 8.40.
Figure 8-47. Removing Plunger.
4. Remove the two thru (larger) bolts. See Figure
8-48.
Figure 8-46. Solenoid Removed from Starter.
Phillips Head
Screws
Torx Head Screws