8 - 12
– +
ELEC
IGNITION SYSTEM
EAS00753 EAS00754
11.Starting circuit cut-off relay
• Disconnect the starting circuit cut-off relay
coupler from the wire harness.
• Connect the pocket tester (
Ω
×
1) to the
starting circuit cut-off relay coupler as
shown.
• Check the starting circuit cut-off relay for
continuity.
Positive tester probe
→
blue/yellow
1
Negative tester probe
→
blue/black
2
Continuity
Positive tester probe
→
blue/black
2
Negative tester probe
→
blue/yellow
1
No
continuity
NOTE:
_
When you switch the positive and negative
tester probes, the readings in the above chart
will be reversed.
• Are the tester readings correct?
YES
NO
Replace the starting
circuit cut-off relay.
12.Wiring
• Check the entire ignition system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
• Is the ignition system’s wiring properly
connected and without defects?
YES
NO
Replace the ignitor
unit.
Properly connect or
repair the ignition
system’s wiring.