7 - 39
FI
AIR INDUCTION SYSTEM
EAS00510
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
• hoses
Loose connection
→
Connect properly.
Cracks/damage
→
Replace.
• pipes
Cracks/damage
→
Replace.
2. Check:
• reed valve
1
• reed valve stopper
• reed valve seat
Cracks/damage
→
Replace the reed valve.
3. Measure:
• reed valve bending limit
a
Out of specification
→
Replace the reed
valve.
1
Surface plate
Reed valve bending limit
0.4 mm (0.016 in)
4. Check:
• air cut-off valve
Cracks/damage
→
Replace.