Altitudes can also be displayed in meters. Note that the altitude tape does not change scale.
Displaying altitude in meters:
1) Press the PFD Softkey to display the second-level softkeys.
2) Press the ALT UNIT Softkey.
3) Press the METERS Softkey to turn on metric altitude readouts.
4) Press the
BACK
Softkey to return to the top-level softkeys.
When the altitude is displayed in meters, the large and small
ALT
Knobs adjust the Selected Altitude in 500
meter and 50 meter increments respectively.
A magenta Altitude Trend Vector extends up or down the left of the altitude tape, the end resting at the
approximate altitude to be reached in six seconds at the current vertical speed. The trend vector is not shown
if altitude remains constant or if data needed for calculation is not available due to a system failure.
The barometric pressure setting is displayed below the Altimeter in inches of mercury (in Hg) or hectopascals
(hPa) when metric units are selected. Adjusting the altimeter barometric pressure setting creates discontinuities
in VNV vertical navigation, moving the descent path. For large adjustments, it may take several minutes for the
aircraft to re-establish on the descent patch. If the change is made while nearing a waypoint with a VNV Target
Altitude, the aircraft may not re-establish on the descent path in time to meet the vertical constraint.
Selecting the altimeter barometric pressure setting:
Turn the BARO Knob to select the desired setting.
Selecting standard barometric pressure (29.92 in Hg):
1) Press the PFD Softkey to display the second-level softkeys.
2) Press the STD BARO Softkey.
Changing altimeter barometric pressure setting units:
1) Press the PFD Softkey to display the second-level softkeys.
2) Press the ALT UNIT Softkey.
3) Press the IN Softkey to display the barometric pressure setting in inches of mercury (in Hg).
Or, press the HPA Softkey to display the barometric pressure setting in hectopascals (hPa).
4) Press the
BACK