Garmin DA40 GPS Receiver User Manual


 
Garmin G1000 Pilot’s Guide for the Diamond DA40/40F
190-00592-06 Rev. A
SYSTEM
OVERVIEW
FLIGHT
INSTRUMENTS
EIS
AUDIO PANEL
& CNS
FLIGHT
MANAGEMENT
HAZARD
AVOIDANCE
AFCS
ADDITIONAL
FEATURES
APPENDICESINDEX
500
APPENDIX B
4) After the update completes, the PFD continues to power-up normally.
5) Turn the G1000 System OFF and remove the SD card.
6) Repeat steps 1 through 4 for the MFD. The MFD and PFD databases are now updated. Remove the SD card
when finished.
7) Verify the correct update cycle is loaded during MFD power-up.
GARMIN DATABASES
NOTE: The data contained in the terrain and obstacle databases comes from government agencies. Garmin
accurately processes and cross-validates the data, but cannot guarantee the accuracy and completeness of
the data.
The following G1000 databases are stored on Supplemental Data Cards provided by Garmin:
•Expanded basemap –The basemap database contains data for the topography and land features, such as
rivers, lakes, and towns. It is updated only periodically, with no set schedule. There is no expiration date.
•Terrain–Theterraindatabasecontainsterrainmappingdata.Itisupdatedperiodicallyandhasnoexpiration
date.
•Airportterrain–Theairportterraindatabasecontainsairportdiagramdata.Itisupdatedperiodicallyand
has no expiration date.
•Obstacle–Theobstacledatabasecontainsdataforobstacles,suchastowers,thatposeapotentialhazardto
aircraft. Obstacles 200 feet and higher are included in the obstacle database. It is very important to note that
not all obstacles are necessarily charted and therefore may not be contained in the obstacle database. This
database is updated on a 56-day cycle.
•SafeTaxi – The SafeTaxi database contains detailed airport diagrams for selected airports. These diagrams aid
in following ground control instructions by accurately displaying the aircraft position on the map in relation
to taxiways, ramps, runways, terminals, and services. This database is updated on a 56-day cycle.
•FliteCharts – The FliteCharts database contains procedure charts for the United States only. This database
is updated on a 28-day cycle. If not updated within 180 days of the expiration date, FliteCharts no longer
functions.
Since these databases are not stored internally in the PFD or MFD, a Supplemental Data Card containing
identical database versions must be kept in each display unit. After subscribing to the desired databases
product, these database products will be downloaded to two Supplemental Data Cards (with the exception of
FliteCharts, which is loaded on only one card). Insert each Supplemental Data Card into the correct location
shown in Figure B-3. If one of the Supplemental Data Cards contains the ChartView database, or the FliteCharts
database, this card must be inserted into the bottom card slot on the MFD. These cards must not be removed
except to update the databases stored on each card.