TIMERS
The G1000 timers available include:
•Stopwatch-likegenerictimers(availablefromthePFDTimer/ReferencesWindowandontheMFDAUX-
Utility Page)
•Total-time-in-ighttimer(MFDAUX-UtilityPage)
•Timesincedeparture(MFDAUX-UtilityPage)
The generic timer can be set to count up or down from a specified time (HH:MM:SS). When the countdown
on the timer reaches zero the digits begin to count up from zero. If the timer is reset before reaching zero
on a countdown, the digits are reset to the initial value. If the timer is counting up when reset, the digits are
zeroed.
Setting the generic timer (PFD):
1) Press the
TMR/REF
Softkey.
2) Turn the
large FMS
Knob to select the timer field (hh/mm/ss).
3) Use the FMS Knob to enter the desired time and press the
ENT
Key.
4) With the UP/DN field highlighted, turn the
small FMS
Knob to select the timer counting direction.
5) Press the
ENT
Key.
6) With ‘START?’ highlighted, press the
ENT
Key to start the timer. The field changes to ‘STOP?’.
7) To stop the timer, press the ENT Key with ‘STOP?’ highlighted. The field changes to ‘RESET?’.
8) To reset the timer, press the ENT Key with ‘RESET?’ highlighted. The field changes back to ‘START?’ and the
digits are reset.
9) To remove the window, press the
CLR
Key or the
TMR/REF
Softkey.
Figure 1-34 Generic Timer (Timer/References Window)
PFD