Using the Auto ID function with a LAN daisy-chain
• The LAN2 RJ45 (output) of a display must connect to the LAN1 RJ45 (input) on the next display in
a daisy-chain.
• Each display must have a unique IP address assigned.
• Network hub devices must not be used to create multiple branches of displays along the LAN daisy-
chain. All displays must be connected sequentially.
• The LAN2 RJ45 of the last display in the daisy-chain must not be connected back to the network
(do not form a network loop).
• Monitor IDs are automatically assigned sequentially starting at Monitor ID 1.
• Monitor IDs are assigned based on the physical LAN cable connection order - not the IP address
assignment order.
• All displays must be powered on when performing the Auto ID function.
• The Auto ID function should only be performed from the rst display in the daisy-chain. Do not
perform Auto ID from displays further along the daisy-chain.