Specifications
Specifications
Velocity Transducer
Method Doppler Principle
Accuracy* ±2% of reading; Zero Stability: ±1.52 cms (±0.05 fps)
Range -1.52 to 6.1 m (-5 to +20 fps)
Resolution 0.3 cms (0.01 fps)
Response Time 4.8 seconds
Profile Time 4.8 seconds
Probe Dimensions
Length: 6.9 cm (2.7 in.)
Width: 3.81 cm (1.5 in.)
Height: 1.1 cm (0.44 in.)
Cable Urethane sensor cable, shielded
Cable Length 7.6 m (25 ft), custom cable lengths up to 100 ft
Mounting
Dedicated Mounting Rings (mounting clips recommended for pipe diameters 8 in. or
under), Mounting Plate (for permanent mounting—drills to pipe wall), Adjustable
Mounting Band Kit
Connection Sensor connector to Quick connect hub or bare leads connection via terminal block.