9.12 Draft measurement
9.12.1 Draft measurement incorrect
Failure on LevelDatic equipment
Check LevelDatic equipment. See separate documentation in "As-
built drawings and user's manual"-binder.
Incorrectly configured data for draft measurement.
Check that configured ship data in Ship measures-window on Work
Station correspond to real distances on ship.
Faulty communication with LevelDatic equipment.
See chapter 9.1.10.
9.13 Load Calculator
9.13.1 Values displayed on TankRadar and load calculator differ.
Ullage values differ due to a delay of information during quick loading or
discharging, especially in small tanks.
When the surface is stable, wait for approximately one minute to see
that the values become equal.
Concentrate on ullage values displayed on TankRadar since they are
updated more often than on the load calculator.
Trim/List correction is set to off on Work Station, but the protocol to the
load calculator is using trim/list corrected values.
Check setting of trim/list correction in the Setup-window. See
Operating Manual.
Presentation units changed from m to feet or vice versa.
Check setting of units in the Setup-window. See Operating Manual.