Service Manual
Third edition, June 1997
3.10 Level Unit – Temperature Data
The Temperature Data-window shows the dynamic data and
the database values for the temperature measurement.
Select a new tank by hitting the Tank-button or by hitting the
up or down arrow keys.
The dynamic data box shows:
Int temp. The internal temperature measured by a
sensor inside the Transmitter is displayed.
Temp avg. The average temperature calculated as the
average of the values from the sensors that are im-
mersed in the liquid.
Temp 1, 2 or 3. The value from each individual sensor is
displayed.
The following status are shown:
Note: Temperature sensor number 1 is the lowest sensor. If only
two sensors are used, these will be number 1 and 2, with number 1
as the lowest.
TX comfail indicates that the transmitter is not commu-
nicating. This produces an alarm on the alarm row.
Int temp fail. The internal temperature measurement
has failed when the box is checked.
Avg error. This box is checked if it was not possible to
calculate any average temperature. For example if there
is no temperature sensor in the liquid.
Temp 1, 2 or 3 fail. This temperature sensor does not
produce an acceptable value.
Int Temp valid. This box is checked when the internal
temperature sensor is producing an acceptable value.