Saab G3 Automobile Accessories User Manual


 
69
Service Manual
Third edition, June 1997
Note: The level and level rate always based on the same unit. If one
of them is changed, the other changes as well.
Temp: 0 = degrees Celsius
1 = degrees Fahrenheit
Press: 0 = mbar
1 = PSI (pounds per square inch)
5.9.4 Local Display Frame
Select Disp to change the display mode of the Local Display.
Each tank can have its own display mode.
Enter a digit from 0 to 3 to change the display mode.
Mode: 0 = Display is off
1 = Ullage
2 = Toggle between ullage, temperature and
IG pressure.
3 = Data directly from the Work Station.
5.9.5 Register Frame
The Register frame is used for viewing and changing data in
the registers in the LCI and LCM database. See chapter 3.21
for a list of the registers.
There are two types of registers, the database and dynamic
registers. The database registers contain static register that
can be changed while the dynamic registers contain dynamic
values that are continuously measured or calculated.
The registers are shown in order starting with register 0.
New registers can be viewed either by pressing the up or
down arrow keys or by entering the register number and
pressing the Enter-key. Four registers are shown at a time on
the display.
The values are shown as either decimal or hexadecimal
values. When the values are hexadecimal, an H is displayed
after the value.
You can also use the Enter-key to move the cursor in the
frame.
If two LCMs are included in the system, both are updated
when database values are changed.
5.9.6 FiltDist Frame
This frame is used for viewing the Filter Distance of the
Transmitters. The frame shows three filter distances at a time.