9.9.2 Indicated inert gas pressure always the same
IG pressure sensor’s opening to the tank may be clogged.
Clean the sensor’s opening to the tank. See chapter 6.4.
IG pressure sensor faulty.
Replace sensor, see chapter 6.4.
9.10 Tank Display Unit
9.10.1 Display on TDU not working.
No voltage supply
Check fuses in TDU-Power Supply. See chapter 8.2.
Check power cables and DC distribution to TDUs.
Communication failure
Check communication cables
Check I/O Box. See chapter 4 and 9.4.
9.11 Portable Readout System:
9.11.1 Indication of communication error (CERR) on PRU.
Low walkie-talkie battery voltage
Charge battery. This may be necessary even if voice communication
works.
Bad radio conditions.
Move PRU (walkie-talkie) to another position. This may be necessary
even if voice communication works.
Check base radio antenna.
Low volume control on either radio.
Increase volume control.
Incorrectly adjusted squelch control on either radio.
Adjust squelch (if any) to low level without noise between
transmissions.
9.11.2 No voice communication between walkie-talkie and base radio (PRS).
No power supply.
Check batteries in walkie-talkie and power supply to base radio.
Unit faulty.
Replace units one by one: base radio, walkie-talkie, PRU, PRS
Interface Board in I/O Box.
Cable faulty.
Check the cabling between base radio and I/O Box.
9.11.3 No display on PRU.
Low walkie-talkie battery voltage
Walkie talkie battery needs to be recharged
PRU cable faulty.
Replace cable.
PRU faulty.
Replace.