Third edition, June 1997
Contact fault between Work Station and I/O Box or between I/O Box and
Level Unit.
Check cable and connectors.
Serial port Com 1 or Serial Interface Board in Work Station faulty.
Check Service window “Communication I/O Box” on Work Station.
See chapter 3.30.
The RS 485 Interface Board in location Com 4 in I/O Box faulty.
Check that LEDs in I/O Box are flashing, see chapter 4.
Interface Board (LCI) in Level Unit faulty.
See chapter 5.7.
9.1.3 SysFail message: Level Unit Power Failure.
Power failure to LI.
Check status of LIs in Service window Level Unit: LI Status. See
chapter 3.16
Check fuses in the Power Block (LP), see chapters 5.11 and 10.
9.1.4 SysFail message: Level Unit LI Communication Failed.
Contact fault on cable between Calculation Unit and Transmitter Interface
(LI).
Check status of LIs in Service window Level Unit: LI Status. See
chapter 3.16.
Check cables and connectors inside the Level Unit.
Check if LCM is functioning, see chapter 9.1.7.
Check setting of switch for addressing of the LI, see chapter 5.10.5.
Power failure to LI.
See chapter 9.1.3 above.
LI faulty.
Replace LI. If the system is equipped with more than one LI, try
exchanging the LIs. See chapter 5.10.8 “Replacing a Transmitter
Interface”. Check result.
9.1.5 SysFail message: I/O Box Communication Failed.
Mains power supply to I/O Box failing.
Check that I/O Box has power and is running. See chapter 4.
Communication cables faulty.
Open the cover and watch the LEDs on the main board at the bottom
of the box. See chapter 4.1.
Check communication cables.
Serial Interface Board in Work Station faulty.
Restart the Work Station (if more than one Work Station – restart the
Master Work Station) by pressing the Reset-button. See chapter 3.1.
9.1.6 Warning message: Level Unit Ground Failure.
Ground Failure on one or more LIs.
Read chapter 9.14 for information on how to find the cause of the
ground failure.