Saab G3 Automobile Accessories User Manual


 
21
Service Manual
Third edition, June 1997
Note: When setting the Level Unit into one-tank measurement
mode, there is no measurement on the other tanks.
Select a new tank by hitting the Tank-button or by hitting the
up or down arrow keys.
The tank number is the internal number in the TankRadar
system and is useful when setting the addresses on the op-
tional Tank Display Units, see chapter 8.1. It is also the num-
ber that is used when communicating with other systems
such as load calculators or ship host computers.
The tank address corresponds to the terminal on the Trans-
mitter Interface to which the Transmitter is connected. Tank
addresses 1-15 are connected to LI 1, addresses 16-30 to LI 2,
31-45 to LI 3 and 46-60 to LI 4.
The tank address is usually the same as the tank number.
However, they do not need not be the same.
The dynamic data is status or data that is continuously being
measured and presented. These values can not be changed
by the operator.
Ullage is the distance from the TankRadar reference
point down to the surface of the product in the tank.
Innage is the distance from the bottom up to the surface
of the product.
Level rate is the rate at which the surface of the product
moves as the tank is loaded or discharged. Positive
values indicate that the surface moves upwards.