Saab G3 Automobile Accessories User Manual


 
53
Service Manual
Third edition, June 1997
3. Select “Backup one file”.
4. Select the log file you want to save. Its name has an
extension “.log”. These are normally placed in the
directory acu/tmp.
5. Order the copying to start.
3.33 Service Log-Window
Select Service Log from the Service-menu to open the Service Log-window. It
is used when there is a need to store measured data for a later analysis. The
log software regularly stores time, channel status and channel value into a
log file. The log file is named “dl<mm><dd><hh>.log” where <mm> is the
month (01-12), <dd> is the the day (01-31) and <hh> is the hour (00-23). If the
log is restarted within the same hour the previous log was started, previous
log data is lost. The log file can be copied onto a DOS-diskette, see Backup
below.
The Service Log-window is used to setup the logging of the measured values.
Sample time The time between the logged samples. It can be set to
between 10 and 99999 seconds.
Max samples in The maximum number of entries in
one file the log file before a new log file is created (typically 20
000).
#channels Number of channels to be logged, between 0 and 20.
Ta g Channel tag with seven characters. For example
“CT01ULL” for ullage of first tank or “CT01RAT” for
level rate of first tank.
Sign A -sign indicates that the channel can have positive
and negative values, such as level rate.