Saab G3 Automobile Accessories User Manual


 
30
Service Manual
Third edition, June 1997
3.13 Level Unit – Trim/List Data
The Trim/List Data-window shows the measured trim and
list angles. They are displayed as 1/100 of degrees.
The source of the trim and list values are shown in the Ship
measures-window in the Configure-part of the software.
Open the Ship measures-window by hitting the Window-key
and selecting Configure. Then hit the Picture-button and
select Calculation and Ship data.
The dynamic data box is divided into three parts for LCI,
LCM 1 and LCM 2. The LCM 1 and 2 read trim and list val-
ues produced by the Trim/List Unit mounted in the Level
Unit cabinet. The LCI receives its trim and list values from
draft sensors, separate inclinometer, from external communi-
cation or if it is manually entered.
The status boxes show.
Trim or list sens fail. The sensor in question is faulty.
Trim or list manual. This box is checked if manual
values for trim and list have been entered.
In the database box the following is shown and can be
changed:
LT sensor type. Enter 0 if no trim and list sensor is
connected. Enter a 1 if the standard Trim/List Unit is
used.
Trim or list offset. If you find that the trim/list values
displayed by TankRadar are not correct, their offset can
be programmed in the database box. The offset is
shown in 1/100 degrees angle. For example, enter 5 to
set a 0.05° offset.