Specifications
Model Selection Guide
Revision 7 HercuLine™ 2000 Series Actuator - Installation, Operation and Maintenance Manual 11
7/08
2002 2003
TABLE VI - OPTIONS Selection
Local keypad/ No local display interface supplied
(Note 2) 0_ _ _ _ _
display Integrally mounted local display/keypad interface
1_ _ _ _ _
Local Auto/ No auto/manual switch _ 0_ _ _ _
manual switch Auto/manual switch with "Out of Auto Contact"
_ 1_ _ _ _
Auto/manual switch with "Out of Auto Contact"
_ 2_ _ _ _
Handwheel No Handwheel _ _ 0_ _ _
Handwheel
_ _ 1_ _ _
Certificates None
_ _ _ 0 _ _
Certificate of Conformance _ _ _ 1_ _
Approvals UL Type 4/IP66, CSA
(Note 4) _ _ _ _ 0_
CE _ _ _ _ 1_
Shipped Rotation Counter clockwise shaft rotation on increasing signal
_ _ _ _ _0
Clockwise shaft rotation on increasing signal
_ _ _ _ _1
TABLE VII - COMMUNICATIONS/PROTOCOL
None No communications option board or protocol 0
Modbus RTU RS485 RS-485 Modbus compliant - standard with EEU 1
HART 5 HART Communications Protocol 2
TABLE VIII - MANUALS
Standard English 0
TABLE IX - FACTORY OPTIONS
Factory Options None
Restrictions
a
IV _ 00 IV _ 60, _ 80
II II
II II
ACCESSORIES
Mounting Hardware Mounting plate adapter for Barber Colman Series MP495
Mounting plate adapter for Landis & Staefa SQM53/56
Direct Couple Valve Hardware
North American Valve Retrofit Kit
Linkage Assembly Ball joint for 5/16" dia. Pushrod
Pushrod 12 in. (304,5 mm) long, 5/16 " dia.
Pushrod 18 in. (457,2 mm) long, 5/16 " dia.
Pushrod 24 in. 609,6 mm) long, 5/16 " dia.
Pushrod 48 in. (1219,2 mm) long, 5/16 " dia.
HART Turk Cable for Handheld Connection 51452352-501
Handheld Config.
HercuLink
TM
Palm Software
(Note 3)
Battery powered 232/485 converter with cable
Remote Mount Remote 4-20 mA requires 135 ohm fdbk, 120V 50/60Hz
Control Remote 4-20 mA requires 1000 ohm fdbk, 120V 50/60Hz
Remote 4-20 mA requires 135 ohm fdbk, 220V 50/60Hz
Remote 135 ohm input requires 135 ohm fdbk, 120V 50/60Hz
Notes:
1. 135 ohm available by parallelling 1K potentiometer with 158 Ohm resistor (supplied).
2. HercuLink
TM
software (pn 51452354-509), RS232/485 converter (pn 51452354-510),
customer supplied Palm
TM
PDA running OS3.5 or higher and Palm serial cable are required
for the 2001 and 2002 actuators if no display is selected.
3. Requires PDA manufacturer's serial interface cable.
4. CSA approval is good for 75°C and a maximum relay load of 3.5 amps or 70°C with a
relay load of 5 amps.
00
51452354-506
51452354-507
51452354-503
51452354-511
51452354-504
51452354-505
51452354-501
51452354-502
2000 2001
Available Only With
Table Selection
Not Available With
150
090
R7195A1056
R7195B1021
R7195A1064
51452354-508
R7195A1031
51452354-510
51452354-509
Restriction
Letter
c
150
090
b