1394 Password Management Commands
passwords lock-out
Use the passwords lock-out command in Global Configuration mode to
strengthen the security of the switch by locking user accounts that have failed
login due to wrong passwords. When a lockout count is configured, a user
who is logging in must enter the correct password within that count.
Otherwise that user is locked out from further switch access. Only a user with
read/write access can reactivate a locked user account. Password lockout does
not apply to logins from the serial console. Use the no form of this command
to set the password lockout count to the default value.
Syntax
passwords lock-out
1-5
no passwords lock-out
Parameter Description
This command does not require a parameter description.
Default Behavior
The default value is 0 or no lockout count is enforced.
Command Mode
Global Configuration mode.
User Guidelines
Password lockout only applies to users with authentication configured to
local. RADIUS or TACACS authenticated users will use policies configured
on the respective RADIUS/TACACS servers.
Example
The following example sets the number of user attempts before lockout at 2.
console(config)#passwords lock-out 2