Intel TIGI2U Automobile Accessories User Manual


 
Server Platform Features
System Cooling
All system components except the power supply cage are cooled by a set of fans mounted
near the middle of the chassis and behind the hard drive bays. The TIGI2U system comes
in a non-redundant, four-fan configuration that consists of two 80mm x 38mm fans and two
40mm x 28mm fans.
Air flows in through the front bezel over the peripheral bay and the hard drive bays,
passes through the fans and over the baseboard, and exhausts through the rear of the
chassis. Each fan provides tachometer signal output to the server baseboard to indicate a
fan failure.
The cooling subsystem contains a fan array consisting of two 80 x 38 mm fans and two 40
x 28 mm fans to cool the server board and other components. A fan failure is indicated by
one of the fault LEDs located on the front panel.
Hardware Requirements
To avoid integration difficulties and possible board damage, your system must meet the
requirements outlined below. For a list of qualified components, see the links under
Additional Information and Software.”
Processor
The server board accommodates two Intel® Xeon™ 3.2 GHz processors operating at 800
MHz FSB with 2MB cache.
Intel
®
Carrier Grade Server TIGI2U User Guide
28