Server Platform Features
Server Platform Front Panel
1 0
Alarms
Status
ID ONNIC
CRT MNR PWRMJR
TP01645
N
O
Q
R
S
T U
P
1 0
Alarms
Status
ID ONNIC
CRT MNR PWRMJR
A
B
C ED F
H
I
K M
G
J
L
Front Panel Buttons
A Power button Toggles the system power
B Reset button Resets the system
G NMI button Assert NMI to baseboard
H ID button Toggles system ID LED
Front Panel LEDs
C Critical (amber) When continuously lit, indicates the presence of a Critical System Fault. A
critical system fault is an error or event that is detected by the system with a
fatal impact to the system. In this case, the system cannot continue to
operate. An example is the loss of a large section of memory that renders the
system not operational. The front panel critical alarm relay will be engaged.
D Major (amber) When continuously lit, indicates the presence of a Major System Fault. A
major system fault is an error or event that is detected by the system that has
discernable impact to system operation. In this case, the system can continue
to operate but in a “degraded” fashion (reduced performance or loss of non-
fatal feature reduction). An example is the loss of one of two mirrored disks.
The front panel major alarm relay will be engaged.
E Minor (amber) When continuously lit, indicates the presence of a Minor System Fault. A
minor system fault is an error or event that is detected by the system but has
little impact on actual system operation. An example is a correctable ECC
error. The front panel minor alarm relay will be engaged.
F Power (amber) When continuously lit, indicates the presence of a Power System Fault. The
front panel power alarm relay will be engaged.
I System ID LED (white) Continuously lit when activated either by a software command or by the front
panel ID button.
continued
Intel
®
Carrier Grade Server TIGI2U User Guide