Emerson 3300 Radar Detector User Manual


 
Reference Manual
00809-0100-4811, Rev CA
February 2006
4-5
Rosemount 3300 Series
Volume Configuration For volume calculations you can choose one of the standard tank shapes or
the strapping option. Choose None if volume calculation is not used.
Tank Type
You can choose one of the following options:
Strap table
Vertical Cylinder
Horizontal Cylinder
Vertical Bullet
Horizontal Bullet
Sphere
•None
Strapping Table
Use a strapping table if a standard tank type does not provide sufficient
accuracy. Use most of the strapping points in regions where the tank shape is
non-linear. A maximum of 10 points can be added to the strapping table.
Figure 4-3. Strapping points
Actual tank bottom may look like this.
Using only 3 strapping points results in a level-to-volume profile
that is more angular than the actual shape.
Using 6 of the points at the bottom of the tank yields a
level-to-volume profile that is similar to the actual tank bottom.
STRAPPING POINTS