Emerson 3300 Radar Detector User Manual


 
Reference Manual
00809-0100-4811, Rev CA
February 2006
A-15
Rosemount 3300 Series
Model Code 3302, Level and Interface in Liquids
Model Product Description
3302 Guided Wave Radar Level and Interface Transmitter
Code Signal Output
H 4-20 mA with HART
®
communication
Code Housing Material
A Polyurethane-covered Aluminum
Code Conduit / Cable Threads
1 ½ - 14 NPT
2 M20 x 1.5 adapter
3 PG 13.5 adapter
Code Operating Temperature and Pressure
S - 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C)
(1)
(1) Process seal rating. Final rating depends on flange and O-ring selection. See “Process Temperature and Pressure Rating” on page A-4.
H High Temp / High Pressure
(2)
: 2940 psi @ 750 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and 345 bar @ 38 °C) according
to ANSI Class 2500 (Probe Type 3A, 3B and 4A)
(2) Requires option None for sealing (no O-ring). Only for SST (Material of Construction model code 1).
P High Pressure
(2)
. Max 500 °F (200 °C): 3500 psi @ 500 °F and 5000 psi @ 100 °F (243 bar @ 200 °C and 345 bar @ 38 °C)
according to ANSI Class 2500 (Probe Type 3A, 3B and 4A)
Code Material of Construction
(3)
: Process Connection / Probe
(3) For other materials, consult factory.
1 316 / 316 L SST (EN 1.4404)
2 Hastelloy
®
C-276 (UNS N10276). Available for probe type 3B and 4A.
3 Monel
®
400 (UNS N04400). Available for probe type 3B and 4A
7 PTFE covered probe and flange. Available for probe type 4A, Flanged version
8 PTFE covered probe. Available for probe type 4A
Code Sealing, O-ring Material (Consult factory for other o-ring materials)
N None
(4)
(4) Requires High Temperature High Pressure (code H) or High Pressure (code P) probe.
V Viton
®
fluoroelastomer
E Ethylene Propylene
K Kalrez
®
6375 perfluoroelastomer
B Buna-N
Code Probe Type Process Connection Probe Lengths
1A Rigid Twin Lead Flange or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
2A Flexible Twin Lead with weight Flange or 1.5 in. Thread Min: 3 ft 4 in. (1 m). Max: 77 ft 1 in. (23.5 m)
3B Coaxial for interface measurements Flange, 1 or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
4A Rigid Single Lead Flange, 1 or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
Code Probe Length Units
E English (feet, inch)
M Metric (meters, centimeters)
Code Total Probe Length
(5)
(feet/m)
(5) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit. If
tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions.
xx 0 - 77 ft or 0-23 m
Code Total Probe Length
(5)
(inch/cm)
xx 0 - 11 inch or 0-99 cm