Emerson 3300 Radar Detector User Manual


 
Reference Manual
00809-0100-4811, Rev CA
February 2006
Rosemount 3300 Series
A-20
Spare parts list Probe Model 3301/3302
Model Product Description
3309 Spare probe
Code Signal Output
N Not applicable
Code Housing Material
N Not applicable
Code Conduit Threads/Cable Threads
0 Not applicable
Code Operating Temperature and Pressure
S Standard: -15 psig (-1 Bar) to 580 psig (40 Bar) @ 302 °F (150 °C)
(1)
(1) Process seal rating. Final rating depends on flange and O-ring selection, see “Process Temperature and Pressure Rating” on page A-4.
H High Temp / High Pressure
P High Pressure
Code Material of Construction: Process Connection/Probe
1 316 / 316L SST (EN 1.4404), Teflon (PTFE, PFA)
2 Hastelloy C276, Teflon (PTFE, PFA). Available for probe type 3A, 3B and 4A (with plate design if not threaded)
3 Monel 400, Teflon (PTFE, PFA). Available for probe types 3A, 3B and 4A (with plate design if not threaded)
7 PTFE Covered Probe and Flange valid for probe 4A, 5A flanged version only (with plate design)
8 PTFE Covered Probe and Flange valid for probe 4A, 5A
Code Sealing, O-ring Material (Consult factory for other
o-ring materials)
VViton
E Ethylene Propylene
K Kalrez 6375
B Buna-N
N None (HP/HTHP)
Code Probe Type Applicable
for Model
Allowable Process
Connection
Probe Length
1A Rigid Twin Lead. 3301 & 3302 Flange or 1.5 “ Thread Min: 1 ft 11 inch (0.6 m)
Max: 9 ft 10 inch (3 m)
2A Flexible Twin Lead with weight 3301 & 3302 Flange or 1.5 “ Thread Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
3A Coaxial 3301 Flange or 1”, 1.5 “ Thread Min: 1 ft 3 inch (0.4 m)
Max: 19 ft 8 inch (6 m)
3B Coaxial perforated, for interface or easier
cleaning
3301 & 3302 Flange or 1”, 1.5 “ Thread Min: 1ft 3 inch (0.4 m)
Max: 19 ft 8 inch (6 m)
4A Rigid Single Lead 3301 Flange or 1”, 1.5 “ Thread Min: 1 ft 11 inch (0.6 m)
Max: 9 ft 10 inch (3 m)
5A Flexible Single Lead with weight d=4 mm 3301 Flange or 1”, 1.5 “ Thread Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
5B Flexible Single Lead with chuck d=4 mm
(2)
(2) Extra length for fastening is added in factory.
3301 Flange or 1”, 1.5 “ Thread Min: 3 ft 3 inch (1 m)
Max: 65 ft 7 inch (20 m)
Code Probe Length Unit
E English (feet, inch)
M Metric (meters, centimeters)
Code Total Probe Length
(3)
(feet/m)
(3) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit
(see Model String Example). If tank height is unknown, please round up to an even length when ordering - probes can be cut to exact length in field.
Maximum allowable length is determined by process conditions.
xx 0-65 feet or 0-20 m
Code Total Probe Length
(3)
(inch/cm)
xx 0-11 inches or 0-99 centimeters