Actron KAL 3840 Automobile User Manual


 
Continuity Test
Diode Test
Temperature Measurement
DC Ampere Measurement (Current Probe Output)
AC Ampere Measurement (Current Probe Output)
8-5
(AC+DC) Voltage Measurement
RPM Measurement
Frequency Measurement
Ohm Measurement
8-4
Mode
4 cylinder
2 cylinder
Range
120 - 20000 RPM
60 - 10000 RPM
Accuracy
2 RPM
Range
DC 500 mV
DC 5 V
DC 50 V
DC 500 V
DC 600 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
40 Hz ~ 400 Hz
± (0.8 % + 5 d)
400 Hz ~ 10 kHz
± (3.0 % + 5 d)
Accuracy
Function
Frequency
% Duty
Dwell
Pulse Width
Range
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
5 MHz
2.0 % ~ 98 %
3.6 ° ~ 356.4 °
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz
10 Hz
100 Hz
1 kHz
0.1 %
0.1 °
Accuracy
± (0.1 % + 3 d)
Pulse Width > 2 µs
1.2 °/krpm + 2 d
2 µs ~ 450 ms (Pulse Width > 2 µs)
Range
500
5 k
50 k
500 k
5 M
30 M
Resolution
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
Accuracy
± (0.5 % + 5 d)
± (0.75 % + 5 d)
± (0.75 % + 10 d)
Test Voltage
1.2 V
Threshold
Approx. 70 W
Response time
1 ms
Range
2.0 V
Open Circuit Voltage
3.0 V
Accuracy
± (2.0 %5 d)
Range
-50 °C to 1300 °C
-58 °F to 2372 °F
Resolution
0.1 °C
0.1 °F
Accuracy
± 3 °C
± 5.4 °F
Range
30 mA ~ 20 A
100 mA ~ 40 A
40 A ~ 60 A
Resolution
1 mV/10 mA
1 mV/100 mA
1 mV/100 mA
Accuracy
± (1.5 % + 20 mA)
± (2.0 % + 20 mA)
± (4.0 % + 0.3 A)
Range
30 mA ~ 10 A
100 mA ~ 40 A
40 A ~ 60 A
Resolution
1 mV/10 mA
1 mV/100 mA
1 mV/100 mA
40 Hz ~ 1 kHz
± (2.0 % + 20 mA)
± (2.0 % + 20 mA)
1 kHz ~ 5 kHz
± (4.0 % + 30 mA)
± (6.0 % + 30 mA)
Accuracy
± (8.0 % + 0.3 A)