Chapter 5 Command Reference
Programmable Pulse Output (59551A Only)
5-86 Operating and Programming Guide
59551A
This command selects the polarity of the Programmable Pulse on-time edge.
Expanded Syntax
:PULSe:REFerence:EDGE RISing or FALLing
Parameter
The RISing parameter sets the Programmable Pulse rising edge as the on-time
edge.
The FALLing parameter sets the Programmable Pulse falling edge as the
on-time edge.
59551A
This query returns the polarity of the Programmable Pulse on-time edge.
Response
RIS indicates that the Programmable Pulse on-time edge is the rising edge.
FALL indicates that the Programmable Pulse on-time edge is the falling edge.
:PULSe:REFerence:EDGE . . .
:SYSTem:PRESet
Selects the polarity of the Programmable Pulse on-time edge.
RISing
NON-VOLATILE
:PULSe:REFerence:EDGE?
RESPONSE FORMAT
Returns the polarity of the Programmable Pulse on-time edge.
XYZ