Symmetricom 58503B GPS Receiver User Manual


 
Chapter 5 Command Reference
Operating Status
Operating and Programming Guide 5-71
Assessing Receiver Health ______________________
(continued)
This query returns the lifetime count, indicating the total powered-on time.
Response
Range of the integer is 0 to 4,294,967,296 with a resolution of 1. Each count
represents three hours of operation.
This query returns information for user-specified test.
Expanded Syntax
:DIAGnostic:TEST? ALL or DISPlay or PROCessor or RAM or EEPRom or UART or QSPI
or FPGA or INTerpolator or GPS or POWer.
Response
A value of 0 (zero) indicates test passed.
Parameter
ALL returns test information for all of the tests.
:DIAGnostic:LIFetime:COUNt?
RESPONSE FORMAT
Returns the lifetime count, indicating the total powered-on time.
± dd
:DIAGnostic:TEST? . . .
RESPONSE FORMAT
Returns information for user-specified test.
±
dd