Symmetricom 58503B GPS Receiver User Manual


 
Chapter 5 Command Reference
1 PPS Reference Synchronization
5-36 Operating and Programming Guide
Operating in Holdover ____________________________________
"
Initiating Manual Holdover __________________________________
This command places the Receiver in holdover mode. The Receiver will stay in
holdover until you send :SYNC:HOLD:REC:INIT.
Context Dependencies
This command is not valid prior to the first lock following powerup (see bit 2 of
the Powerup Status Register) or :SYSTem:PRESet. Sending this command
before the first lock will generate
error -221
.
See Also
:SYNChronization:HOLDover:RECovery:INITiate
:SYNChronization:HOLDover:INITiate
Places the Receiver in holdover mode.
EVENT