Symmetricom 58503B GPS Receiver User Manual


 
Chapter 5 Command Reference
Operating Status
Operating and Programming Guide 5-55
Monitoring Status/Alarm Conditions ___________
(continued)
!
Clearing and Presetting Alarms (continued)
When the configurable portion of the status/alarm reporting system is preset,
the Receiver is configured to generate an alarm under the factory default set of
operating conditions.
Use this command to restore only the status/alarm reporting system to the
factory (:SYSTem:PRESet) settings.
Theory
The configurable portion of the status/alarm reporting system consists of
enable and transition filter registers. Figure 5-1 identifies the factory default
enables and transitions.
The status/alarm reporting configuration is stored in non-volatile memory.
This command performs a subset of the :SYSTem:PRESet command in that it
only presets the configuration associated with status/alarm reporting system.
This command does not affect condition or event registers.
:STATus:PRESet:ALARm
Presets the status/alarm reporting system to generate an alarm
when a factory default set of operating conditions occurs.
EVENT