Garmin GTP 59 GPS Receiver User Manual


 
Page B-16 G3X Installation Manual – Appendix B
Revision A 190-01115-01
B.3.7 Double-Shield Termination Technique - Method C.1
In rare situations where double shielding may be necessary, the outer shield should be grounded at both
ends, while the inner shield should be grounded only at one end.
All other restrictions set forth for in Table B-8 are applicable.
NOTE
The maximum length of the braids should be approximately 4 inches.
Figure B-12. Method C.1 Double-Shield Termination
Table B-8. Shielded Cable Preparations for Garmin Connectors
Backshell
Size
Number of
Pins
Std/HD
Float Min
(inches)
Float Max
(inches)
Ideal Float
(inches)
Window
Min
(inches)
Window
Max
(inches)
1 9/15 1.25 2.25 1.75 2.75 5.25
2 15/26 1.5 2.5 2.0 3.0 5.5
3 25/44 1.5 2.5 2.0 3.0 5.5
4 37/62 1.5 2.5 2.0 3.0 5.5
5 50/78 1.5 2.5 2.0 3.0 5.5