Garmin GTP 59 GPS Receiver User Manual


 
Page B-14 G3X Installation Manual – Appendix B
Revision A 190-01115-01
Table B-7. Shielded Cable Preparations – (Quick Term)
Backshell
Size
Number of
Pins
Std/HD
Quick
Term
Min
(inches)
Quick
Term
Max
(inches)
Quick
Term
Float
(inches)
1 9/15 1.25 2.25 1.75
2 15/26 1.5 2.5 2.0
3 25/44 1.5 2.5 2.0
4 37/62 1.5 2.5 2.0
5 50/78 1.5 2.5 2.0
B.3.5. Shield Termination-Method B.2 (Daisy Chain-Quick Term)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure B-10). All other restrictions and instructions for the shield termination technique set forth for
Method B.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately
4 inches.
Figure B-10. Method B.2 (Daisy Chain-Quick Term) for Shield Termination