Mitsubishi Electronics QJ72LP25GE Automobile Electronics User Manual


 
108
SD4
Error
information
categories
Error
information
category code
• Error information is stored in Error common information (SD5 to
SD15) and Error individual information (SD16 to SD26).
• This register stores a category code indicating an error information
type.
• The common information category codes store the following codes:
0: No error
1: Module No. (Slot No./CPU No./Base No.)
*1
2: File name/drive name
3: Time (value set)
4: Program error location
5: Reason(s) for system switching (for the Q4AR and Redundant
CPU)
6: Reason(s) for tracking size excess error (for the Redundant CPU)
7: Base No./power supply No. (Universal model QCPU: This applies
to modules with a serial number (first five digits) of "10042" or later.)
8: Tracking transmission data classification (for the Redundant
CPU)
*1 For the multiple CPU system using the Basic model QCPU, High
Performance model QCPU, Process CPU, and Universal model
QCPU, the module No. or CPU No. is stored according to an
error.
(For details, refer to each error code.)
CPU No. 1: 1, CPU No. 2: 2, CPU No. 3: 3, CPU No. 4: 4
• The individual information category codes store the following codes:
0: No error
1: (Empty)
2: File name/drive name
3: Time (value actually measured)
4: Program error location
5: Parameter number
6: Annunciator (F) No.
7: CHK instruction failure No. (Except for the Basic model QCPU
and Universal model QCPU)
8: Reason(s) for system switching failure (for the Redundant CPU)
12: File diagnostic information (for the Universal model QCPU)
13: Parameter No./CPU No. (for the Universal model QCPU)
S
(Error)
New
Rem
No. Name Meaning Explanation
Set by
(When Set)
Corres-
ponding
ACPU
D9
Corres-
ponding
CPU
Individual information category
code
Common information category
code
B15 B7 B0B8to to