Emerson 3812 Automobile Parts User Manual


 
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 3: Electrical installation
3-9000-765 Rev D March 2013
Frequency/Digital outputs 57
Frequency or Digital Outputs (FODO 3) source
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
F
O1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
F
requency output 1A is based on frequency content (Actual - Uncorrected Flow Rate)
F
requency output 1B is based on frequency content and Frequency 1B Phase
F
requency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
F
requency output 2B is based on frequency content and Frequency 2B Phase
D
igital output 1A is based on Digital output1A content (Frequency 1A Validity and Flow
Direction)
D
igital output 2A is based on Digital output2A content (Frequency 1A Validity and Flow
Direction)
Digital output
2A is based on Digital output 2A content (Frequency 2A Validity and Flow
Direction)
D
igital output 2B is based on Digital output 2B content (Frequency 2B Validity and Flow
Direction)
Mode options
Open Collector (requires external excitation supply voltage and pull-up resistor)
T
TL (internally powered by the meter 0-5 VDC signal)
Channel B Phase options:
Lag forward, Lead reverse (Phase B lags Phase A while reporting forward flow, leads Phase
A while reporting reverse flow)
L
ead forward, Lag reverse (Phase B leads Phase A while reporting forward flow, lags Phase
A while reporting reverse flow)
Phase A and Phase B output (based on flow direction)
Reverse flow - output only reports flow in the reverse direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
F
orward flow - output only reports flow in the forward direction. For frequency outputs,
Phase B of the output is 90 degrees out of phase with Phase A.
A
bsolute - output reports flow in both directions. For frequency outputs, Phase B of the
output is 90 degrees out of phase with Phase A.
Bidirectional - output reports flow on Phase A only in the forward direction and on Phase
B only in the reverse direction.