Emerson 3812 Automobile Parts User Manual


 
42 Appropriately rated lifting slings
Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual
March 2013 3-9000-765 Rev D
6. NEVER allow the slings to contact the electronics enclosure or the transducer shrouds.
Damage to the meter may occur. If the slings do come in contact with the electronics or
the shroud, temporarily remove the head from the meter during the lifting operation
(remove the four bolts holding the enclosure to its base and unplug the cable from the
Acquisition Module. Two screws hold this cable in place.) Use a spreader-bar on the
sling to prevent contact with the electronics or the transducer shroud.
7. Once the lifting operation is complete, reattach and secure the electronics cable to J3
on the Acquisition Module, return the electronics enclosure to its original position,
replace the bolts, and secure the enclosure in place. Lifting the meter with the upper
enclosure installed but with out the bolts installed, may cause the electronics to fall and
cause personal injury or electronics damage.
Figure 2-12 Incorrect sling attachment
8. NE
VER apply shock loads to the meter. Always lift the meter gradually. If shock loading
ever occurs, the slings must be inspected per manufacturer's procedures prior to being
placed in any further service.