36 Use of appropriate safety engineered swivel hoist rings in meter end flanges
Section 2: Mechanical installation Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual
March 2013 3-9000-765 Rev D
9. Direct mount option: NEVER allow the slings to contact the electronics enclosure.
Damage to the enclosure may occur. Use a spreader bar with the slings to prevent
contact with the electronics enclosure and the base enclosure (
see Figure 2-11). If the
slings do come in contact with the electronic enclosure then remove the four bolts
holding the e
nclosure to its base and temporarily remove the head from the meter
during the lifting operation. You will need to unplug the cable on the Acquisition
Module. Two screws hold this cable in place. Once the lifting operation is complete,
reattach and secure the electronics cable on the Acquisition Module, return the
electronics enclosure to its original position, replace the bolts, and secure the enclosure
in place.
Lifting the meter with the upper enclosure installed but without the bolts installed, may
c
ause the electronics to fall and cause personal injury or equipment damage.
Figure 2-10 Sling contacting electronics enclosure