Barco IP-2003 Automobile Accessories User Manual


 
Manual # 26-0302000-00 / Revision E ImagePRO – Multi Format Image Processor
53
Valid "nnn" fields can range from 000 to 255. As with any selection line, the user must press the SEL button to begin
editing the IP values. At this point, the first value is highlighted. Turning the knob moves the value through the range
0 to 9. When the desired value is found, the user presses SEL. This moves the highlight to the next value, and the
process repeats. After every 3 digits, a ‘.’ will automatically be placed. The final SEL (at the last value) completes the
edit, turning off edit mode. Pressing ESC at any point before the final SEL press will abort the edits and leave the
address value unchanged. It is necessary to set the Subnet mask and Gateway address before setting the IP address
field. Only after setting the IP address will ImagePRO attempt to set the Ethernet port. An IP address of
000.000.000.000 indicates that the user is not interested in Ethernet communication and the Ethernet port will be
ignored.
NOTE:
It takes several seconds for the unit to communicate with the Ethernet port and set the IP address. During
this time the SEL key will remain lit.
When all the Ethernet setup is done, the operator can communicate with the ImagePRO via the Ethernet. Use the IP
address and port 10001. On a Microsoft Windows PC, open a command prompt window and type the following on the
prompt and press ENTER:
> telnet xxx.xxx.xxx.xxx 10001
Once Ethernet communication is established, the telnet window functions in a similar fashion to a serial COM port
communication. Consult the network administrator to make sure the ImagePRO can communicate with the PC.
SET IP
SUB nnn.nnn.nnn.nnn
GW nnn.nnn.nnn.nnn
IP nnn.nnn.nnn.nnn