Narrow Band Radio Setup
Late TX Limit
The value entered for this parameter (measured in milliseconds) sets the maximum
allowable deviation time from the start of a response window during which an 8525
G2/8530 G2 can make a transmission. After this threshold, the transmission will not
be attempted and the 8525 G2/8530 G2 will try again at the next opportunity. For
example, suppose this parameter is set to 5. From the beginning of the response
window, the 8525 G2/8530 G2 can be up to 5 milliseconds late sending a
transmission. Beyond this threshold, the transmission is not attempted. The
vehicle-mount waits for the next opportunity.
The allowable range for this parameter is from 1 and 10 – the default value is 2.
Test Polling Values
Tap on the Test Polling Values button to test the polling values indicated in
this dialog box without committing them to memory.
To commit the new polling values to memory:
Tap on the OK button – the dialog box is closed and the new values
are saved.
To discard the new values, and retain the existing values:
Tap on the X button at the top of the dialog box.
5.5.8.4 Power Tab
Enable Power Saving
When this parameter is checked, power saving is enabled.