Yamaha YZ450FA Automobile User Manual


 
7-28
FUEL INJECTION SYSTEM
Fault code No. 23
Symptom Atmospheric pressure sensor signal is not received properly.
Fail-safe system Able to start
Able to drive
Diagnostic code No. D02
FI diagnostic tool dis-
play
Atmosphere
Checking method Measure the atmospheric pressure.
Item Item/components and probable cause Check or maintenance job Checking method
1 Check the connection and locking con-
dition of the atmospheric pressure sen-
sor coupler.
Disconnect the coupler and check the
pins. (bent or broken terminals and
locking condition of the pins)
Poor connection Properly
connect, repair, or replace.
Set the switch on the
FI diagnostic tool sub-
wire harness to "ON",
and then check the
fault code display.
Fault code number
is not displayed
Service is finished.
Fault code number
is displayed Re-
fer to item 2.
2 Check the connection and locking con-
dition of the wire harness ECU coupler.
Disconnect the coupler and check the
pins. (bent or broken terminals and
locking condition of the pins)
Poor connection Properly
connect, repair, or replace.
Set the switch on the
FI diagnostic tool sub-
wire harness to "ON",
and then check the
fault code display.
Fault code number
is not displayed
Service is finished.
Fault code number
is displayed Re-
fer to item 3.
3 Continuity of harness Open or short circuit Re-
place.
Between atmospheric pres-
sure sensor coupler and
ECU coupler.
(Black/Blue–Black/Blue)
(Pink–Pink)
(Blue–Blue)
Set the switch on the
FI diagnostic tool sub-
wire harness to "ON",
and then check the
fault code display.
Fault code number
is not displayed
Service is finished.
Fault code number
is displayed Re-
fer to item 4.