Section 7: Replacement Procedures
SATO M10e Service Manual PN 9001113A Page 7-15
CIRCUIT BOARD FUSE REPLACEMENT
The M10e Printer has four fuses; two are wired to the power supply while the other two are
directly connected to the main circuit board.
1 Switch off the printer and disconnect the power supply cord.
2 Remove the top, front, and left housing covers to expose fuses (1, Figure 7-12).
3 Detach fuses (1) located on main circuit board (2) and determine their condition.
4 Replace fuses (1) as required.
5 Reattach left side cover.
6 Complete the Factory Reset procedure as provided in this manual.
Figure 7-12, Fuse Replacement
NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance
on housing cover removal.
NOTE: The condition of a fuse may be determined by two methods; either by
visually inspecting the fuse filament for voids or by using a meter to
determine conductivity.
NOTE: Figure 10-1 of the Diagrams & Schematics section provides guidance
on housing cover installation.
NOTE: Section 9 contains the Factory Reset procedures.
I
E
E
E
1
2
8
4
+
R
S
B
O
A
R
D
1
2
1