Section 8: Adjustment Procedures
SATO M10e Service Manual PN 9001113A Page 8-11
Figure 8-8, Eye-Mark Sensor Adjustments
3 Connect test module (3) to main circuit board connector (4).
4 Turn dial (5) on test module (3) to position number 4.
5 Connect the positive (+) probe of the multimeter to pin SIG (7) on test module (3).
6 Connect the negative (-) probe of the multimeter to pin GRD (8) on test module (3).
7 Ensure the multimeter is for DC voltage reading.
8 Place a label without the eye-mark part in position to be read by the sensor.
9 Adjust VR5 potentiometer (2) so that the multimeter value is less than 0.5 volts.
10 Replace the label without the eye-mark with one that has the eye-mark for sensor reading.
11 Observe the multimeter for a value of +1.0 volts more than the prior value read.
12 Repeat steps 8 through 11 until the value is 1.0 volts.
13 Test print labels to ensure proper function.
14 Disconnect test module (3) from main circuit board (1).
15 Disconnect test module (3) from main circuit board (1) and replace housing covers.
NOTE: Refer to TP Test Module Usage in the TRoubleshooting section for
additional instruction on test module usage.
0
1
2
8
7
6
5
4
3
G
N
D
S
I
G
1
A
2
A
3
A
4
A
6
B
5
B
4
B
3
B
1
B
2
B
6
A
5
A
5A
6A
2B
1B
3B
4B
5B
6B
4A
3A
2A
1A
S
I
G
G
N
D
3
4
5
6
7
8
2
1
0
3
3
5
7
6
1
I
E
E
E
1
2
8
4
+
R
S
B
O
A
R
D
2
4