Trimble Outdoors 5700/5800 GPS Receiver User Manual


 
9 Default Settings
78 5700/5800 GPS Receiver User Guide
5700 GPS Receiver Operation
All 5700 receiver settings are stored in application files. The Default
application file, Default.cfg, is stored permanently in the receiver, and
contains the factory default settings for the 5700 receiver. Whenever
the receiver is reset to its factory defaults, the current settings (stored in
the Current application file, Current.cfg) are reset to the values in the
Default application file.
You cannot modify the Default application file. However, if there is a
Power Up application file (Power_Up.cfg) in the receiver, the settings in
this file can be applied immediately after the Default application file,
overriding the factory defaults.
For more information about application files, see Application Files,
page 52.
9.1 Default Settings
Table 9.1 shows the default settings for the 5700 receiver, as defined in
the default application file.
Table 9.1 Default settings
Function Factory Default
SV Enable All SVs enabled
General Controls: Elevation mask 13°
SNR mask 7
RTK positioning mode Low Latency
Motion Kinematic
Power Output 3 Disabled
1PPS time tags Off
ASCII time tags Off
Serial Port 1: Baud rate 38400
Format 8-None-1
Flow control None