12.2 Output Status for Errors and Alarms
Error indication Measured value
indication
Current output
(4-20mA)
Totalization
pulse output
Remarks
(Note 1)
(Note 3) Stopped
After power-up,
no measurement starts.
(Note 3) Stopped
After power-up,
no measurement starts.
(Note 2)
Zero
(Note 3) Stopped
―――――――
Zero
(Note 3) Stopped
Still water zero adjustment
cannot be performed.
Zero
(Note 3) Stopped
Still water zero adjustment
cannot be performed.
Zero
(Note 3) Stopped
Still water zero adjustment
cannot be performed.
Measured data
Measured data Measured data
The error message
disappears if you clear
(reset) the totalizer count.
Measured data Measured data Measured data
―――――――
Measured data Measured data Measured data
―――――――
Measured data Measured data Measured data
―――――――
Measured data Measured data Measured data
―――――――
Note 1: The display and output may not be correct depending on the nature of the ROM error.
Note 2: If a parameter failure relating to the current output occurs, the current output may not become
the value as specified by the setting when an alarm occurs.
Note 3: The current output value used in case an alarm occurs will be output. For setting method, see
8.2.16, “420mA Alarm Output Setting.”