Raymarine 631 PLUS GPS Receiver User Manual


 
6-14 SL520/530/631 PLUS Chartplotter Displays
Display Unit
Connection
Power and NMEA Input Connection
The DC power and NMEA input should be connected at the rear Power/
NMEA seven-pinconnector. Theconnector(viewedfrom the outside)and pin
functions are shown in the following diagram and table. The NMEA Input is
detailed in Section 6.8.
f
Figure 6-8: Power and NMEA Connector
Power Connection
CAUTION:
If the power connections are accidentally reversed the system will not
work. Use a multimeter to ensure that the input power leads are
connected for correct polarity.
Switch off the display unit before you remove the power cord.
The RED wire must be connected to the feed from the positive (+) battery
terminal and the BLACK wire to the feed from the negative () battery
terminal. The shielded wire (screen) should be connected to the shipsRF
ground as previously described in Grounding the System on page 6-12.
Any unused wires should be insulated and taped back.
Pin No. Function Color
1 Channel 1 NMEA data input (+ve) Orange
2 Channel 1 NMEA return (-ve) Yellow
3 Battery negative Black
4 Shield (drain wire) No insulation
5 Battery positive (12/24/32 V systems) Red
6 Channel 2 NMEA data input (+ve) Green
7 Channel 2 NMEA return (-ve) Blue
2
1
4
3
5
7
6