4.) Appearance, external cracks, discoloration, leakage. When measured capacitance
of he capacitor has reduced below 85% of the rating, change the capacitor.
Figure 2 Time Replacement Chart
6-2 Relays
To prevent a contact fault, etc., relays must be changed according to the number of accumulative switching
times (switching life is approximately 30,000 rides).
6-3 Projector Bulb
To prevent an excessive down time, due to the projector bulb burning out, obtain a spare bulb whenever the
INFOCUS run time states over 750 hours. We do not know at this time how long this bulb lasts. This is
only a suggestion for having on hand this spare part, not a requirement.
Note: Projector bulbs can be obtained from Infocus direct by ordering from a local distributor or going on
the internet to ( WWW.INFOCUS.COM
). Also the projector is warranted by Infocus direct by a pass
through warranty. Any maintenance done to the projector will void the warranty. Should you require a
loaner, Infocus will overnight delivery you a loaner for a fee if given a major credit card.
6-4 NONDESTRUCTIVE TEST LIQUID PENETRANT METHOD
• Remove all paint a minimum of one inch of the weld area.
• Clean area with solvent and allow to dry.
• Apply penetrant to test area allowing ample time to seep into openings.
• Remove penetrant remaining on surface without removing the penetrant from openings.
• Apply developer.
• Visually examine the weld for penetrant indications in the developer coating.
• Once again clean the tested area of developer and any traces of penetrant.
Part Name
Cooling Fan
Smoothing Capacitor Main Ckt.
Smoothing Capacitor Control Brd.
Standard Replacement Interval
2to3Years
5 Years
5 Years
Description
Change as Required
Change as Required
Change the board as requd.
Change as Required
Re
lays
-------------------