Visually inspect for slip, trip and fall hazards in the queue area.
Check for sharp or protruding objects in or around the queue area.
Check the condition, content and location of all signs.
Check the condition and security of the stairs/platform.
8. Building Fire Alarm Interface (If installed)
The VR2000 is equipped with an Occupants Panic Stop capability, which is used to stop the ride at the
occupants’ request. The circuit is paralleled into the NO contact of the fire alarm system. In case of a fire,
the facility’s fire alarm system will trip, closing the NO contact, thereby initiating the “Panic Stop” circuit.
Upon circuit activation, the system will return to the “Home” position, the video image will freeze and the
sound will stop. If power remains, the platform will be lowered to the platform using the normal operating
procedure. If power fails, the system will be lowered to the platform using the “without power” procedure
of paragraph 2-13C of the Operators Manual page 7. Also, upon lowering the unit to the platform, the
attendant will manually release the hood and manually release the restraint harness by removing the hold
pin and manually raise the harness off of the patron. This procedure requires approximately 30 seconds.